中文名称:大鼠血栓素B2(TXB2)酶联免疫试剂盒
-
货号:CSB-E08047r
-
规格:96T/48T
-
价格:¥3900/¥2500
-
其他:
产品详情
-
产品描述:
This rat TXB2 ELISA Kit is suitable for qualitatively determining rat concentrations in serum, plasma, or tissue homogenates in vitro. TXB2, an inactive metabolite/product of thromboxane A2, is a potent vasoconstrictor and platelet aggregating agent. It is important in the platelet-release reaction and induces irreversible platelet aggregation. TXB2 has been measured in a variety of clinical entities, particularly in coronary artery disease, where plasma elevations have been reported in coronary vasospasm.
This kit uses the quantitative sandwich-based enzyme immunoassay technique to measure the amount of rat TXB2 in the sample. Standards and samples are respectively added to the microplate wells pre-coated with an anti-rat TXB2 antibody. Biotin-labeled TXB2 antibody, HRP-avidin, and TMB substrate are pipped into the microplate in turn. The capture antibody pre-coated on the plate captures the TXB2 in the rat samples. TXB2 binds to the biotinylated anti-TXB2 rat monoclonal antibody. And the biotin on the biotinylated anti-TXB2 rat monoclonal antibody binds to the avidin on the enzyme label, forming immune complexes. The color renders blue after the addition of the TMB substrate. The addition of the stop solution into the wells immediately turns the blue into yellow. The concentration of TXB2 in the samples is directly proportional to OD (450nm). Each manufactured lot of this ELISA kit was quality tested for criteria such as sensitivity, specificity, precision, linearity, and lot-to-lot consistency.
-
缩写:TXB2
-
种属:Rattus norvegicus (Rat)
-
样本类型:serum, plasma, tissue homogenates
-
检测范围:3.9 pg/mL-250 pg/mL
-
灵敏度:0.97 pg/mL
-
反应时间:1-5h
-
样本体积:50-100ul
-
检测波长:450 nm
-
研究领域:Signal Transduction
-
测定原理:quantitative
-
测定方法:Sandwich
-
精密度:
Intra-assay Precision (Precision within an assay): CV%<8% Three samples of known concentration were tested twenty times on one plate to assess. Inter-assay Precision (Precision between assays): CV%<10% Three samples of known concentration were tested in twenty assays to assess. -
线性度:
To assess the linearity of the assay, samples were spiked with high concentrations of rat TXB2 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay. Sample Serum(n=4) 1:1 Average % 94 Range % 88-98 1:2 Average % 95 Range % 91-102 1:4 Average % 99 Range % 94-106 1:8 Average % 93 Range % 87-97 -
回收率:
The recovery of rat TXB2 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section. Sample Type Average % Recovery Range Serum (n=5) 96 90-103 EDTA plasma (n=4) 92 88-98 -
标准曲线:
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed. pg/ml OD1 OD2 Average Corrected 250 1.990 1.890 1.940 1.785 125 1.298 1.198 1.248 1.093 62.5 0.786 0.766 0.776 0.621 31.25 0.545 0.525 0.535 0.380 15.6 0.341 0.321 0.331 0.176 7.8 0.292 0.272 0.282 0.127 3.9 0.215 0.211 0.213 0.058 0 0.156 0.154 0.155 -
数据处理:
-
货期:3-5 working days
引用文献
- Thymol co-administration abrogates hexachlorobenzene-induced reproductive toxicities in male rats AS Tijani,Human & experimental toxicology,2023
- Cardio-protective and Anti-atherosclerosis Effect of Crocetin on Vitamin D3 and HFD-induced Atherosclerosis in Rats L Yu,Journal of oleo science,2021
- The therapeutic effect of Ilex pubescens extract on blood stasis model rats according to serum metabolomics Di Cao .et al,Journal of Ethnopharmacology,2018
- Prostacyclin, thromboxane and glomerular filtration rate are abnormal in sickle cell pregnancy Obilade OA.et al,PLoS One.,2017
- Anti-atherosclerosis and cardio-protective effects of the Angong Niuhuang Pill on a high fat and vitamin D3 induced rodent model of atherosclerosis Wen-Juan Fu.et al,J Ethnopharmacol. ,2017
- Use of a balanced dual cyclooxygenase-1/2 and 5-lypoxygenase inhibitor in experimental colitis. Pallio G.et al,Eur J Pharmacol.,2016
- Effect of consumption of fresh and heated virgin coconut oil on the blood pressure and inflammatory biomarkers: An experimental study in Sprague Dawley rats Mohammad Afiq Hamsi et al,Alexandria Journal of Medicine,2015
- Mechanisms underlining gender differences in Phenylephrine contraction of normoglycaemic and short-term Streptozotocin-induced diabetic WKY rat aorta U.I. Aloysius et al,Brain Research,2012
相关产品
Most popular with customers
-
Human Transforming Growth factor β1,TGF-β1 ELISA kit
Detect Range: 23.5 pg/ml-1500 pg/ml
Sensitivity: 5.8 pg/ml
-
-
-
Mouse Tumor necrosis factor α,TNF-α ELISA Kit
Detect Range: 7.8 pg/ml-500 pg/ml
Sensitivity: 1.95 pg/ml
-
-
-
-