中文名称:人细胞角蛋白21-1片段(CYFRA21-1)酶联免疫试剂盒
-
货号:CSB-E09606h
-
规格:96T/48T
-
价格:¥3200/¥2500
-
其他:
产品详情
-
产品描述:
This Human CYFRA21-1 ELISA Kit was designed for the quantitative measurement of Human CYFRA21-1 protein in serum, plasma. It is a Sandwich ELISA kit, its detection range is 0.312 ng/mL-20 ng/mL and the sensitivity is 0.078 ng/mL .
-
缩写:CYFRA21-1
-
种属:Homo sapiens (Human)
-
样本类型:serum, plasma
-
检测范围:0.312 ng/mL-20 ng/mL
-
灵敏度:0.078 ng/mL
-
反应时间:1-5h
-
样本体积:50-100ul
-
检测波长:450 nm
-
研究领域:Others
-
测定原理:quantitative
-
测定方法:Sandwich
-
精密度:
Intra-assay Precision (Precision within an assay): CV%<8% Three samples of known concentration were tested twenty times on one plate to assess. Inter-assay Precision (Precision between assays): CV%<10% Three samples of known concentration were tested in twenty assays to assess. -
线性度:
To assess the linearity of the assay, samples were spiked with high concentrations of human CYFRA21-1 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay. Sample Serum(n=4) 1:1 Average % 86 Range % 82-90 1:2 Average % 98 Range % 91-105 1:4 Average % 99 Range % 94-110 1:8 Average % 92 Range % 86-99 -
回收率:
The recovery of human CYFRA21-1 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section. Sample Type Average % Recovery Range Serum (n=5) 89 80-98 EDTA plasma (n=4) 97 90-105 -
标准曲线:
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed. ng/ml OD1 OD2 Average Corrected 20 2.541 2.385 2.463 2.305 10 2.229 2.082 2.156 1.998 5 1.607 1.545 1.576 1.418 2.5 0.866 0.842 0.854 0.696 1.25 0.463 0.439 0.451 0.293 0.625 0.337 0.324 0.331 0.173 0.312 0.254 0.246 0.250 0.092 0 0.160 0.156 0.158 -
数据处理:
-
货期:3-5 working days
引用文献
- Nano-modified screen-printed electrode-based electrochemical immunosensors for oral cancer biomarker detection in undiluted human serum and saliva samples P Gulati,Nanoscale advances,2024
- Upregulation of the oestrogen target gene SIX1 is associated with higher growth speed and decreased survival in HCV‑positive women with hepatocellular carcinoma RM Critelli,Oncology Letters,2022
- Identification of a serum biomarker panel for the differential diagnosis of cholangiocarcinoma and primary sclerosing cholangitis Joy Cuenco.et al,Oncotarget,2018
问答及客户评论
May I know are the antibodies used in the ELISA kit polyclonal antibodies or monoclonal antibodies?
Human cytokeratin fragment antigen 21-1 (CYFRA21-1) ELISA Kit
Capture:mouse monoclonal antibody;Detection:goat polyclonal antibody
If further questions,pls let me know.
Most popular with customers
-
Human Transforming Growth factor β1,TGF-β1 ELISA kit
Detect Range: 23.5 pg/ml-1500 pg/ml
Sensitivity: 5.8 pg/ml
-
-
-
Mouse Tumor necrosis factor α,TNF-α ELISA Kit
Detect Range: 7.8 pg/ml-500 pg/ml
Sensitivity: 1.95 pg/ml
-
-
-
-