中文名称:人高铁血红蛋白(MHB)酶联免疫试剂盒
-
货号:CSB-E09493h
-
规格:96T/48T
-
价格:¥3600/¥2500
-
其他:
产品详情
-
产品描述:
This Human MHB ELISA Kit was designed for the quantitative measurement of Human MHB protein in serum, plasma. It is a Sandwich ELISA kit, its detection range is 0.47 μg/mL-30 μg/mL and the sensitivity is 0.11 μg/mL .
-
缩写:MHB
-
种属:Homo sapiens (Human)
-
样本类型:serum, plasma
-
检测范围:0.47 μg/mL-30 μg/mL
-
灵敏度:0.11 μg/mL
-
反应时间:1-5h
-
样本体积:50-100ul
-
检测波长:450 nm
-
研究领域:Others
-
测定原理:quantitative
-
测定方法:Sandwich
-
精密度:
Intra-assay Precision (Precision within an assay): CV%<8% Three samples of known concentration were tested twenty times on one plate to assess. Inter-assay Precision (Precision between assays): CV%<10% Three samples of known concentration were tested in twenty assays to assess. -
线性度:
To assess the linearity of the assay, samples were spiked with high concentrations of human MHB in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay. Sample Serum(n=4) 1:100 Average % 86 Range % 80-91 1:200 Average % 87 Range % 83-93 1:400 Average % 90 Range % 87-93 1:800 Average % 95 Range % 91-103 -
回收率:
The recovery of human MHB spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section. Sample Type Average % Recovery Range Serum (n=5) 96 90-101 EDTA plasma (n=4) 88 82-96 -
标准曲线:
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed. µg/ml OD1 OD2 Average Corrected 30 2.281 2.113 2.197 2.095 15 1.913 1.851 1.882 1.780 7.5 1.596 1.516 1.556 1.454 3.75 1.099 1.097 1.098 0.996 1.88 0.567 0.526 0.547 0.445 0.94 0.312 0.304 0.308 0.206 0.47 0.208 0.201 0.205 0.103 0 0.104 0.100 0.102 -
数据处理:
-
货期:3-5 working days
引用文献
- The Effect of Nitrate-Contaminated Drinking Water and Vegetables on the Prevalence of Acquired Methemoglobinemia in Beit Lahia City in Palestine J Shaban,Water,2023
- Eccentric Cycling Training Improves Erythrocyte Antioxidant and Oxygen Releasing Capacity Associated with Enhanced Anaerobic Glycolysis and Intracellular Acidosis YC Huang,Antioxidants,2021
- Fatal methemoglobinemia due to acute inhalation of methyl nitrite in an industrial accident Huang S,J Forensic Sci,2020
Most popular with customers
-
Human Transforming Growth factor β1,TGF-β1 ELISA kit
Detect Range: 23.5 pg/ml-1500 pg/ml
Sensitivity: 5.8 pg/ml
-
-
-
Mouse Tumor necrosis factor α,TNF-α ELISA Kit
Detect Range: 7.8 pg/ml-500 pg/ml
Sensitivity: 1.95 pg/ml
-
-
-
-